Johnson & Starley Ltd. Heat Bank Thermal Store Units Installation, Commissioning, Servicing, & Users Instructions
System F Everest Heat Bank Thermal Stores
Publication ZZ 09/10/00 Copyright DPS 1041-3
Heat Bank Thermal Store System HBPP System F Everest combination unit Single Heat Exchanger (30 ltr/min) Indirect 35mm Foam Insulation High duty primary coil S-Plan primary controls Fitted programmer Fitted Primary Pump, 6m head All fitted controls are wired Thermostatic Blending Valve 22mm 28mm Primaries Backup Immersion Heater Primary Feed from Store
Unit ID
HBPP450-210-S28
Capacity [litres]
210
Base Diameter [mm]
450
Overall Diameter [mm]
520
Height [mm]
1720
1 Integral Feed & Expansion Tank 2 Plate Heat Exchanger 3 Heat Exchanger Pump 4 Flow Switch 5 Thermostatic Blending Valve, Mixcall III 6 Manual Air Vent 7 Automatic Air Vent 8 Filling Vent 9 Feed to Ball Valve 10 Isolating Valve 11 Y-Pattern Strainer (supplied loose) 12 Overflow (supplied loose) 13 Cold Feed / Expansion 14 Immersion Heater 3kW Incaloy with Stat 16 Cold Mains In, 22mm 17 Hot Mains Out, 22mm 18 Drain Cock 19 Flow From Boiler 28mm 21 Flow to Primary Coil 22 Return from Primary Coil 23 Flow to Heating 28mm 25 By-Pass Connection 15mm 26 Primary Pump UPS 15/60 29 Primary Coil Balancing Valve 31 Primary Feed / Expansion Connection 33 Programmer Danfoss CP715 34 Room Thermostat Danfoss RMT230 (supplied loose) 35a Two Port Zone Valve - Hot Water 22mm 35b Two Port Zone Valve - Heating 28mm 38 Cylinder Thermostat Danfoss ATC 40 Tight Fitting Lid 42 Wiring Centre